VPS - Vacuum Processing Systems - Home
Vacuum Cycling Nucleation (VCN) VCN Technology About Vacuum Processing Systems Contact Vacuum Processing Systems News/Press VPS - Vacuum Processing Systems - Home
SOLVENT VCN SYSTEMS > FLEXIBLE TEMPERATURE

Varible Temperature Cleasning System

This varible temperature cleaning system uses methylene chloride at temperatures up to 150 F. The unit completely evacuates prior to solvent introduction to the chamber so as to allow for temperature operations above the normal boiling point of the solvent. The cleaning is performed under pressure to assure effective cleaning. Operating above atmospheric pressure enhances the cleaning efficiency of many solvents.

The unit above uses perchloroethylene at 200 F. Vacuum to Vacuum systems can vapor degrease with solvents below their normal boiling point. This allows for the use of effective solvents at lower temperatures.

back